HōlHōm+ Meter Connection

Connecting your HōlHōm+ to your meter will allow your HōlHōm+ to receive your electricity usage information from the Meter Data Collector every minute. You are able to view this information on your HōlHōm+ teaching smart thermostat screen, using the Myenergate web portal or using your MyEnergate mobile application.

The Meter Data Collector works with HōlHōm+’s built-in Meter Data Receiver.  The collector attaches to the meter provided by your electricity provider where it gathers information about your energy consumption and transmits it to HōlHōm+.

The Meter Data Collector communicates with HōlHōm+ only.

If you have a ZigBee-enabled smart meter you can use HōlHōm to connect to your meter.  See HōlHōm Meter Connection instruction.

Installing the Meter Data Collector

Important Safety Precautions

Install your Meter Data Collector on a dry day and take all necessary safety precautions, particularly if you need to use a ladder for installing it. In addition, please read and apply the safety instructions below at all times.

  • Do not immerse the Meter Data Collector’s sensor unit in any liquid.
  • Do not drop or cause any sudden impact to the sensor unit.
  • If disposing of the sensor unit, do so in accordance with your local waste disposal regulations.
  • Take precautions when handling batteries. They can cause injuries, burns, and/or property damage as a result of contact with metal objects, heat, and corrosive materials.
  • Read all the instructions carefully before using your Meter Data Collector.

Verify the Contents of the Box

Verify that your box contains all these components in addition to this installation guide. If any item is missing, please contact your reseller.

MDCContents

Install the Batteries in the Sensor Unit

Turn the screw counter-clockwise to open the sensor unit battery compartment cover.

Insert two AA batteries in the orientation indicated by the + and – signs printed on the circuit board, then close and lock the battery compartment by turning the screw clockwise. Do not over tighten. The red STATUS indicator should illuminate within 10 seconds.

DO NOT remove the grease from around the battery lid. This grease helps protect the internal components from moisture.

>

Batteries

Verify Your Meter’s Watt-Hour Multiplier (Kh, Ks or Kt)

The Meter Data Collector works only with digital (electronic) meters with a disk emulator that uses a watt-hour multiplier between 0.1 and 3000.0. The watt-hour multiplier is sometimes called a disk or pulse constant.

The watt-hour multiplier is indicated on the face of the meter, usually with the letters Kh (less often the letters Ks or Kt). In most cases, the watt-hour multiplier is 7.2 if it has dials and a spinning mechanical disk, or 1.0 if it has a digital readout.

 


Determine Your Meter Type

In some cases, it may be necessary to adjust your sensor unit to fit your particular meter. Therefore, it is extremely important to determine exactly what kind of meter is installed on your premises.

Locate your meter and use the following illustrations to determine its type.

Type 1 - Electromechanical


 

Type1Meter

This type of meter has dials and a spinning disk.

The sensor reads the revolutions of the disk and transmits the information to HōlHōm+/Foundation.


Type 2 - Optical Port On The Face, 1.5 Inches Or More From The Outer Rim

 

Type2Meter

On this type of meter, the optical port is located at least 1.5 inches (37 mm) from the meter’s outer rim.

If in doubt, measure the distance using a ruler.

Note: The optical port can be located at either the right (3 o’clock) or left (9 o’clock) position on your meter.


 
Type 3 - Optical Port On The Face, Less Than 1.5 Inches From The Outer Rim

 

Type3Meter

On these meters, the optical port is on the face, located less than 1.5 inches (37 mm) from the meter’s outer rim.

If in doubt, measure the distance using a ruler. (One is printed at the end of this guide.)

This type of meter may require you to mount the supplied rubber shims on the underside of the sensor.

For example, Elster RS1/REX meters require one shim. Elster RS2 and Sensus iCon A Residential meters do not require a shim.


 
Type 4 - Optical Port On The Top

 

Type4Meter

On this type of meter, the optical port is located on the top portion of the meter.

This kind of meter requires you to reconfigure the sensor and install the clear alignment template.

Prepare Your Sensor Unit

Instructions: Perform the operations that correspond to your meter type. When you are done, go to Install Your Sensor Unit.

Prepare Sensor

 
Type 1 - Electromechanical

  1. Open the Sensor Arm latch (G) by pulling upward.
  2. Extend the Sensor Arm (B) to its full length by pulling on it firmly, but gently. If you accidentally pull it out completely, push it back into the casing.
  3. Close the latch (G).

PrepareType1


Type 2 - Optical Port On The Face, 1.5 Inches or More From the Outer Rim

  1. Open the Sensor Arm latch (G) by pulling upward.
  2. Ensure that the Sensor Arm (B) is pushed in as far as it will go into the body of the sensor unit.
  3. Close the latch (G).

PrepareType2


 
Type 3 - Optical Port On The Face, 1.5 Inches Maximum From The Outer Rim

For examples of meters and the number of shims they require, see the Type 2 Meter information in Determine Your Meter Type.

  1. Open the Sensor Arm latch (G) by pulling upward.
  2. Extend the Sensor Arm (B) to its full length by pulling on it firmly, but gently. If you accidentally pull it out completely, push it back into the casing.
  3. Close the latch (G).
  4. Peel off the adhesive backing from the shim.
  5. Position the shim on the underside of the sensor unit casing with the adhesive side down (that is, so that it sticks to the back of the sensor unit).
  6. Press the shim in place onto the underside of the sensor unit casing.

PrepareType1

ShimPrepareType32PrepareType33


 
Type 4 - Optical Port On Top

  1. Open the Sensor Arm latch (G) by pulling upward.
  2. Gently pull the Sensor Arm (B) completely out of the body of the sensor unit.
  3. Turn over the Sensor Arm (B).
  4. Push the thin end of the Sensor Arm (B) upwards through the latch opening and press the Sensor Arm firmly into the cavity.
  5. Firmly push the Sensor Head (C) behind the strap, and as far down as it can go into the bottom cavity of the body. The dark red Optical Sensor (D) must be clearly visible below the clamp. If necessary, use a dull pointed object, such as a ballpoint pen to push the head (C) downwards.
  6. Tuck the wire (E) into the side cavity (F).
  7. Close the latch (G).

PrepareType1PrepareType-42PrepareType-43 

Install Your Sensor Unit

Please read Important Safety Precautions before starting the installation.

Important: Turn on a high energy-consuming appliance in your house, such as your electric stove or dryer. This temporarily increases your electricity consumption and enables the sensor to begin reading your meter’s output in less time.

  1. Go to your meter, taking the following items with you:
  • This guide
  • Sensor unit
  • A clean damp cloth
  • 1 large flat-head screwdriver
  • Clear alignment template (if you have a Type 4 meter)
  • Stepping stool or ladder, if your utility meter is located higher than eye level. DO NOT USE A CHAIR OR OTHER UNSTABLE PLATFORM.
  1. Determine your meter’s Watt-Hour multiplier (Kh) (see Verify Your Meter’s Watt-Hour Multiplier (Kh, Ks or Kt)).
  1. Determine your meter type and perform the appropriate installation steps:

Note: During installation, it is the dark red Optical Sensor (D) that you align with the appropriate optical port on the meter. This is the sensor that is closest to the tip of the sensor head.

Type 1 - Electromechanical
  1. After carefully wiping the meter dome clean with the damp cloth, fit the sensor unit over your utility meter as shown, so that the Sensor Head (C) sits as close as possible to the front of the glass dome.
  2. With your screwdriver, tighten the Clamp (A) until the sensor unit is snug, but can move just enough to allow for slight adjustments. Note: A clamp that is too tight can interfere with proper alignment of the Sensor Head (C) and create communication problems.
  3. Position the Sensor Head (C): Position the Sensor Arm (B) so that it is in line with the spinning disk (use the line on the Sensor Arm as a reference) and the Sensor Head (C) is on or near the center of the meter.
  4. Press and release the RESET button. The red STATUS indicator turns on solid and then starts to flash regularly.
    • Regular flashing indicates that the sensor has detected the signal from your meter. If necessary, adjust the sensor until the indicator is flashes regularly.
  5. If you positioned the Sensor Head (C) correctly, the STATUS indicator starts flashing as indicated below.
    • If it does not, correct the positioning slightly.

ClampSensorPosition

After approximately 20 seconds, the red STATUS indicator turns off and within two minutes, it starts flashing once per disk revolution. This is an indication that your sensor is correctly reading the meter.

Note 1: The STATUS indicator stops flashing after approximately 2 ½ minutes, in order to maximize battery life.

Note 2: If the STATUS indicator does not flash at all and stays lit solid, repeat the steps above and recheck for proper alignment.


 
Type 2 - Optical Port On The Face, 1.5 Inches Or More From The Outer Rim

  1. After carefully wiping the meter dome clean with the damp cloth, fit the sensor unit over your utility meter as shown, so that the Sensor Head (C) sits as close as possible to the front of the glass dome.
  2. With your screwdriver, tighten the Clamp (A) until the sensor unit is snug, but can move just enough to allow for slight adjustments. Note: A clamp that is too tight can interfere with proper alignment of the Sensor Head (C) and create communication problems.Clamp
  3. Position the Sensor Head (C):  Position the Sensor Arm (B) so that the dark red Optical Sensor (D) in the Sensor Head (C) is located exactly above the left optical port. (For example, if the ports are on the right side of the meter, align with the innermost port. For ports on the left, align with the outermost port.)
    • When the sensor arm is positioned correctly, the rib closest to the end of the Sensor Head (C) is aligned with the optical port on the left.
    • Make sure the sensor arm is flush against the meter glass.
      OpticalPorSensorLOpticalPorSensorRSensorHead
  4. Press and release the RESET button. The red STATUS indicator turns on solid and then starts to flash regularly.
  • Regular flashing indicates that the sensor has detected the signal from your meter. If necessary, adjust the sensor until the indicator is flashes regularly.
    SensorStatus
  • If you positioned the Sensor Head (C) correctly, the STATUS indicator starts flashing as indicated below.
    • If it does not, correct the positioning slightly.

Within 20 seconds, the red STATUS indicator starts flashing regularly, indicating that the sensor has detected the signal from your meter. Within 1 minute, in addition to the regular flashing, you should see an extra flash every now and then depending on your rate of electricity consumption. These extra flashes are normal and indicate that the sensor is reading the meter’s output correctly.

Note 1: The STATUS indicator stops flashing after approximately 2 ½ minutes, in order to maximize battery life.

Note 2: If the STATUS indicator does not flash at all and stays lit solid, repeat the steps above and recheck for proper alignment.


 
Type 3 - Optical Port On The Face, 1.5 Inches Maximum From The Outer Rim

  1. After carefully wiping the meter dome clean with the damp cloth, fit the sensor unit over your utility meter as shown, so that the Sensor Head (C) sits as close as possible to the front of the glass dome.
  2. With your screwdriver, tighten the Clamp (A) until the sensor unit is snug, but can move just enough to allow for slight adjustments. Note: A clamp that is too tight can interfere with proper alignment of the Sensor Head (C) and create communication problems.Clamp
  3. Position the Sensor Head (C):  Position the Sensor Arm (B) so that the dark red Optical Sensor (D) in the Sensor Head (C) is located exactly above the left optical port. (For example, if the ports are on the right side of the meter, align with the innermost port. For ports on the left, align with the outermost port.)
    • When the sensor arm is positioned correctly, the rib closest to the end of the Sensor Head (C) is aligned with the optical port on the left.
    • Make sure the sensor arm is flush against the meter glass.
      OpticalPorSensorLOpticalPorSensorRSensorHead
  4. Press and release the RESET button. The red STATUS indicator turns on solid and then starts to flash regularly.
  • Regular flashing indicates that the sensor has detected the signal from your meter. If necessary, adjust the sensor until the indicator is flashes regularly.
    SensorStatus
  • If you positioned the Sensor Head (C) correctly, the STATUS indicator starts flashing as indicated below.
    • If it does not, correct the positioning slightly.

Within 20 seconds, the red STATUS indicator starts flashing regularly, indicating that the sensor has detected the signal from your meter. Within 1 minute, in addition to the regular flashing, you should see an extra flash every now and then depending on your rate of electricity consumption. These extra flashes are normal and indicate that the sensor is reading the meter’s output correctly.

Note 1: The STATUS indicator stops flashing after approximately 2 ½ minutes, in order to maximize battery life.

Note 2: If the STATUS indicator does not flash at all and stays lit solid, repeat the steps above and recheck for proper alignment.


 
Type 4 - Optical Port On Top

  1. Stand directly in front of your meter, at a height where you can see the optical port.
    • The optical port itself looks like a small protruding pipe in the center of the top portion of the meter. Carefully wipe the meter dome clean with the damp cloth.
  2. Hold the template with the protruding tab facing you and the white arrow pointing away from you. Peel off the adhesive backing.
    TopPort
  3. Position the template on the meter so that the horizontal white line on the template follows the front edge of the meter dome, and the white arrow points straight to the optical port.
  4. Carefully stick the template to the dome, pressing it in place on top first, then on the protruding tab down the front of the dome.
    TopPortClamp
  5. Slide the sensor unit over the glass dome and align the edges of the sensor unit body with the white side lines.
  6. Tighten the Clamp (A) until the sensor unit is snug, but can move just enough to allow for adjustments. Note: A clamp that is too tight can interfere with proper alignment of the Sensor Head (C) and create communication problems.
  7. Open the Sensor Arm Latch (G) and sight down the opening. You see a vertical plastic tab painted white on the inside of the sensor unit body.
    SensorArm
  8. Sighting through the opening, position the sensor unit so that the white plastic tab on the body is aligned with the arrow on the template.
  9. Press the RESET button and wait 10 seconds.
    • The red STATUS indicator turns on solid.
      SensorStatus
  10. Keeping the white lines on the body and template aligned, slowly and gently push or pull on the sensor unit until the red STATUS indicator starts flashing regularly, indicating that the sensor has detected the signal from your meter.
    • Within 1 minute, the indicator starts to flash irregularly to indicate that the sensor is reading the meter’s output correctly.

Note 1: The STATUS indicator stops flashing after approximately 2 ½ minutes, in order to maximize battery life.

Note 2: If the STATUS indicator doesn’t flash at all and is steadily lit, repeat the steps above and recheck for proper alignment.

Connect the Meter Data Collector to HōlHōm+

Use the Installer Setup menu to connect HōlHōm+ built-in Meter Data Receiver with the Meter Data Collector.

Note: To successfully pair HōlHōm+ with the Meter Data Collector, you may need to repeat the following steps after fine-tuning the sensor unit’s placement. For information on adjusting the sensor unit’s placement, see Install Your Sensor Unit.
 
Pair the Meter Data Collector with HōlHōm+

Thermostat Home Screen Ensure that the HōlHōm+ Thermostat home screen is displayed.

Press the Menu/Select ButtonSelect_sm button.

image028 Press the Up ButtonUp_sm or Down ButtonDown_sm button to highlight Settings, and then press the Menu/Select ButtonSelect_sm button.
image029 Press the Up ButtonUp_sm or Down ButtonDown_sm button to highlight Installer Setup, and then press the Menu/Select ButtonSelect_sm button.
image030 Press the Up ButtonUp_sm or Down ButtonDown_sm button to highlight Meter Data collector,  and then press the Menu/Select ButtonSelect_sm button.
image031  Press the Up ButtonUp_sm or Down ButtonDown_sm button to highlight Watt-Hour Multiplier, and then press the Menu/Select ButtonSelect_smbutton.
image032  If the Watt-Hour multiplier on your meter is a value other than 1.0, press the Up ButtonUp_sm or Down ButtonDown_sm button to change the value, and then press the Menu/Select ButtonSelect_sm button.

To save changes, select Yes using the Down ButtonDown_sm button, and then press the Menu/Select ButtonSelect_sm button.

image033  Press the Up ButtonUp_sm or Down ButtonDown_sm button to highlight Pair with Collector, and then press the Menu/Select ButtonSelect_sm button.

When prompted to reset the sensor pairing, press the Up ButtonUp_sm or Down ButtonDown_sm button to highlight Yes, and then press the Menu/Select ButtonSelect_smbutton.

image034  When prompted to enter the Installer Password, press the Up ButtonUp_sm or Down ButtonDown_smbutton to highlight the password entry field, and then press the Menu/Select ButtonSelect_sm button.

The default installer password is INST.

To enter the password:

  • Press the ButtonUp_sm or Down ButtonDown_sm buttons to navigate to the appropriate letter or number.
  • Press the Menu/Select ButtonSelect_sm button to select the letter or number and move to the next character in the password.

A screen that confirms HōlHōm+is resetting is displayed, and then HōlHōm+returns to the Meter Data Collector Menu.

SensorStatus Press the Reset button on the sensor unit to complete the connection.

For the expected red STATUS indicaor behavior after resetting (flasing regulary, then irregularly). see Install Your Sensor Unit.

image035 In the Meter Data Collector menu,  press the Up ButtonUp_smor Down ButtonDown_smbutton to highlight Link Info, and then press the Menu/Select ButtonSelect_sm button
image036 Until the connection is complete, the first Link Info screen displays the message Pairing with Collector. Then  HōlHōm+ displays the connection information screen.


Additional Installation Resources

Installation Videos:

Type 1 Electromechanical Meter – Dials and spinning disk.

Type 2 & 3 Front Port Meter – Optical port on the face.

Type 4 Top Port Meter – Optical port on the top.